Wound Type CT for Electrical Panels

Wound Type CT

Variant in Current Transformer: Wound Primary CT

A control transformer is a transformer that is used to step down the voltage to power the control devices of a circuit or machine. The reduced voltage provides a much safer environment for technicians working on the equipment. Residential heating, ventilating, air conditioning systems, and other machines use reduced voltage for the controls, thermostats, relays, and contactors.

Control transformers are often referred to as power supplies. Control transformers with two primary coils and one secondary coil are the most common. A control transformer's primary coils are crossed so that metal links can be used to connect the primaries for 240 V or 480 V operation.

Standard Features of Wound Type CT in Electrical Panels:

  • Comprehensive measurement of class accuracy.
  • Wide range of current ratings and busbar sizes.
  • Tested on high accuracy Automatic CT test system.
  • Used in Switchgears, Distribution systems.
  • Used in Generator, Control panels.
  • Used for Overload protection.
  • Used in Control devices.
  • Used in Energy metering & monitoring.

Why Choose Powertrac Meters for Wound Type CT?

  • Manufactured since 2002 — over 20 years of CT manufacturing experience
  • IS 2705 and IEC 60044-1 compliant wound primary current transformers
  • Every CT tested on high-accuracy automatic CT test system before dispatch
  • Wide current rating range: 1A to 4000A to match any panel specification
  • Comprehensive class accuracy options for metering and protection applications
  • 18-month warranty with dedicated customer support from Jaipur, Rajasthan
  • Custom busbar sizes and CT ratios available on request

Frequently Asked Questions — Wound Type CT for Electrical Panels

Q: What is the difference between a wound type CT and a bar type CT?

A wound type CT has one or more turns of insulated copper wire wound as the primary winding, which provides higher accuracy at low primary currents (typically below 100A). A bar type CT uses a solid bus bar as the single-turn primary, making it suitable for higher current ratings but less precise at low current levels. For electrical panels requiring accurate metering at currents under 100A, wound type CTs are the preferred choice.

Q: What accuracy class is available for Powertrac wound type CTs?

Powertrac Meters wound type CTs are available in metering accuracy classes 0.1, 0.2, 0.5, 1.0, and 3.0, as well as protection classes 5P and 10P — suitable for energy meters, multifunction meters, protection relays, and control devices.

Q: What is the maximum system voltage for Powertrac wound type CT?

Powertrac wound type CTs are rated for a maximum system voltage of 720V, making them suitable for all standard LT (Low Tension) electrical panel applications.

Q: Are Powertrac wound type CTs compliant with IS 2705?

Yes. All Powertrac Meters wound primary CTs comply with IS 2705 Part 1 and IEC 60044-1 and are tested on an automatic CT test system to ensure class accuracy before dispatch.

Q: How do I select the right wound type CT for my electrical panel?

To select the correct wound type CT, identify your primary current (load current), required secondary current (1A or 5A), accuracy class (based on meter type), burden (VA), and busbar dimensions. Contact Powertrac Meters Pvt Ltd at +91-93144-72389 or sales@powertracindia.com for a customised recommendation.

Feature Value
Input Specifications
Current Rating 1 A to 4000 A
Rated Sec . Current 5A or 1 A or as required
Test Voltage 3 KVeff , 50 Hz 1 min / as applicable
System Voltage 720 V max
Outer Insulation Resin / Non - flammable Plastic / Tape (PVC or Fiber Glass)
Protection Class IP 65 ( Resin ) / Ip20
Thermal Short Circuit Current ( Ith ) 60 X In
Rated Continuous Thermal Current ( CTC ) 1.2 In

Note: Technical Specifications and illustrations are subject to change arising out of continuous Product Development.

Related Products for Digital Meter

Copyright © 2023 Powertrac Meters Pvt Ltd | All Rights Reserved | Designed By :   Aunicode International